24/7 HVAC Emergency Service
Live Dispatch SLA · 45-Min Response
Ductwork Engineering & Airflow Division

Custom Duct Fabrication, Aeroseal Sealing & Static Airflow Balancing

Ductwork is the circulatory system of your HVAC installation. Up to 30% of conditioned air is lost through leaking joints, uninsulated attics, and poorly designed plenum transitions. We engineer balanced, silent, high-efficiency duct networks.

airAirflow Standard
400 CFM per Ton
check_circleLeakage Target
< 3% Total Duct Leakage
volume_offAcoustic Floor
Sound-Dampened Liners
architectureSheet Metal
Heavy-Gauge Galvanized
Dignityhvac certified technician performing Duct Work Services
Field Dispatch Active
Unit #DH-104

NATE Master Certified

EPA Universal 608 · Digital Telemetry

On-Duty
Calibrated Diagnostic Instruments Used On This Service:
build_circleDuct Blaster depressurization leakage test system with calibrated digital manometer
build_circleAnemometer airflow hood measuring supply register CFM output directly
build_circleStatic pressure differential probes across supply and return drops
build_circleSmoke pen flow visualization for duct seam leak localization

Common Duct Work Services Issues & Engineering Causes

Derived from our telemetry service logs. Our mobile units carry the exact replacement parts needed to resolve these conditions on the first visit.

01warning

Upstairs Bedrooms Too Hot in Summer, Too Cold in Winter

Technical Root Cause:

Insufficient return air capacity on upper floors and undersized branch ducting causing airflow starvation.

02warning

Loud Popping or Banging Noise When Furnace Starts

Technical Root Cause:

Oil-canning in thin-gauge rectangular ductwork due to rapid thermal expansion and negative return pressure.

03warning

High Electric & Gas Bills from Duct Leakage

Technical Root Cause:

Conditioned air blowing into unconditioned attic spaces through unsealed slip-and-drive cleat joints.

04warning

Dust & Fiberglass Particles Blowing from Vents

Technical Root Cause:

Negative pressure return leaks drawing insulation fibers and dust from attic or crawlspace floor cavities.

05warning

Furnace Overheating from High Static Backpressure

Technical Root Cause:

Restrictive 90-degree square elbows and undersized filter grilles choking required blower CFM.

06warning

Noisy Whistling at Return Air Grilles

Technical Root Cause:

Excessive air velocity exceeding 600 FPM through undersized return grille openings.

Our Duct Work Services Protocol

Every appointment adheres to our verified engineering checklist for lasting comfort and zero callbacks.

01

Duct Blaster Pressure & Leakage Testing

We pressurize the duct system to 25 Pascals to measure total CFM leakage and calculate exact energy loss percentage.

02

Static Pressure & Friction Drop Audit

We test external static pressure (ESP) to ensure blower motors operate within the 0.5 in. W.C. design envelope.

03

Aeroseal & Mastic Sealing

We seal inaccessible internal duct leaks using pressurized Aeroseal sealant particles and brush-on fiber mastic on all joints.

04

Custom Sheet Metal Plenum Transitions

Our sheet metal specialists fabricate aerodynamic radiused elbows and return drops for whisper-quiet airflow.

Frequently Asked About Duct Work Services

Q:What is Aeroseal duct sealing and how does it work?

Aeroseal injects pressurized microscopic non-toxic polymer particles into your blocked duct system. The particles automatically seek out and bond to air leaks, sealing holes up to 5/8-inch wide with a 10-year warranty.

Q:How does duct balancing fix temperature differences between rooms?

We install manual or motorized balancing dampers in branch ducts and use an airflow hood to ensure each room receives exact CFM proportional to its heat gain and loss calculation.

Airflow audits from $149 · Duct sealing & custom fabrication estimates available.

Ready to Schedule Your Duct Work Services?

Connect with a certified dispatch coordinator now. Same-day service available across 36 regional municipalities.